| Processor |
| Processor |
One 650-MHz UltraSPARC®
IIi processor |
| Cache |
Primary: 16 KB data and
16 KB instruction on chip
Secondary: 512 KB external |
| Main
Memory |
| Two PC-133
DIMM slots holding up to 2GB memory |
| Standard
Interfaces |
| Networking |
Two 10/100/1000-Mbps
Ethernet ports |
| Serial |
Two RS-232 serial ports |
| Expansion
Capability |
Up to sixteen Blade
Servers in a single Sun Fire B1600 Blade System Chassis |
| MASS
STORAGE AND MEDIA |
| Internal storage |
One 30GB 2.5-in., 5400
RPM, Ultra ATA 100 24X7 server class drive with 16 MB
buffer and 12 ms average latency |
| External Storage |
Sun StorEdge 3310 NAS
Array |
| Software |
|
Operating system |
Solaris 8 12/02 or later
operating system
Solaris 9 4/03 or later operating system |
| Environment |
| Power
Supply |
Input Rating: (Sun Blade
Platform)
110-240 V AC, 47-63 Hz
12A max at 110V, 6A max at 230V
Average Power Consumption: (Sun Blade Platform)
16 X SPARC® Blades + 2 switches = 650W |
| Temperature |
Operating: 5°C to
35°C (41° F to 95° F)
Non-operating: -40°C to 65°C (-40° F to 149°
F) |
| Relative
Humidity |
Operating: 10% to 90%
Non-operating: 93% |
| Elevation |
Up to 3000 m (70kPa) |
| Regulations |
| Meets
or exceeds the following regulations: |
| Safety |
IEC 60950 (C22.2-60950)
(EN60950) (UL60950) |
| Certification Statements
and Marks |
CULus, TuV-GS, TuV-S,
CCCs&e, C-tick, VCCI-A, BSMI-T, MIC, CE, ICES-A, FCC-A
|
| Emissions and Immunities: |
| RF Radiated Emissions |
CISPR22 (EN55022), Class
B European Union
FCC Part 15, Class B USA, Industry of Canada |
| Conducted Emissions |
CISPR22 (EN55022), Class
B European Union
FCC Part 15, Class B USA, Industry of Canada |
| Harmonic Emissions |
IEC 61000-3-2:2000 (No
Limits) European Union |
| Voltage Flicker |
IEC 61000-3-3:1995/A1:2001
(No Limits) |
| ESD Immunity |
CISPR 24 (EN55024; 8kV
Contact, 15kV Air) IEC 61000-4-2 |
| RF Field Immunity |
CISPR 24 (EN55024, 10V/m)
IEC 61000-4-3 |
Electric Fast
Transient/Burst Immunity |
CISPR 24 (EN55024; 8kV
Contact, 15kV Air) IEC 61000-4-2 |
| Surge Immunity |
CISPR 24 (EN55024; 1kV
I/O, 1kV Power L-L, 2kV Power L-G) IEC 61000-4-5 |
| RF Conducted Immunity |
CISPR 24 (EN55024; 3V
I/O and Power) IEC 61000-4-6 |
| Dimensions
and Weight |
| Blade |
|
| Height |
114.8 mm (4.5 in.) |
| Depth |
338.7 mm (12.5 in.) |
| Width |
26 mm (1 in.) |
| Weight |
1.15 kg (2.5 lb.) |
| Chassis |
|
| Height |
134.4 mm (5.25 in.),
3U |
| Depth |
681 mm (26.5 in.) |
| Width |
448 mm (17.2 in.) |
| Weight |
18.5 kg (53.5 lb.), with
no blade servers; 42.5 kg (93.5 lb.), fully loaded with
16 blade servers |
| Rackmount |
Fits into 19-, 23-, 24-in.,
and 600 mm standard racks |
| Warranty |
| Hardware Support |
1 year parts only |
| Software Install |
90 days |
| Call Responce |
8 hours (Business Day) |
| Deliver |
Return to Depot |