| Processor |
| Number |
Up to 72 |
| Architecture |
UltraSPARC IV and UltraSPARC
III Cu, superscalar SPARC V9, ECC-protected
|
| Cache per
processor |
Level 1: parity-protected
64-KB instruction and 128-KB data on chip (Single-bit
errors are corrected) Level 2: ECC-protected 16-MB
external cache |
| Capacity |
| More than
1/2 TB memory in a single domain |
| Up to 18
fifth-generation fault-isolated Dynamic System Domains |
| Hot-swappable
Uniboard CPU/memory boards, I/O, MaxCPU boards, power,
fans |
| System |
| CPU/Memory
Boards |
Up to 18 Uniboard CPU/memory
boards with four processors each, and up to 32 GB per
board; maximum 576 GB per domain |
| I/O |
Up to 72 hot-swappable
PCI+ I/O slots: 54 slots are 66 MHz; 18 slots are 33 MHz;
supports 10/100 Base-T Ethernet, Gigabit Ethernet, UltraSCSI
(LVD and HVD), ATM, FC-AL, and HiPPI |
| System Interconnect |
150-MHz Sun Fireplane
redundant 18x18 data, address, and response crossbar interconnect. |
| Performance |
| Overall System Bandwidth |
Up to 172.8 GB/sec aggregate
Up to 115.2 GB/sec peak Up to 43.2 GB/sec sustained |
| Overall I/O Bandwidth |
Up to 25.2 GB/sec sustained |
| Availability |
| Hot-swap
CPU, memory, I/O, power, fans, online upgrades, journaling
file system, redundant network connections, redundant
storage connections, hardened operating system kernel,
hardened I/O drivers |
| RAS
Features |
| Standard |
Dynamic Reconfiguration
(DR), Concurrent DR, initiate DR from domain as well as
from System Controller (SC) |
| Dynamic System Domains |
Up to 18 domains allows
secure, fault-isolated, dynamic partitioning of resources
within a single server |
| Security |
| Domain management |
Dedicated network connections
(SC to 18 domains) inside Sun Fireplane interconnect |
| Resource
Management |
| Standard |
Sun's fifth-generation
Dynamic System Domains, Solaris Resource Manager, and
Solaris Bandwidth Manager |
| Software |
| Operating System |
Solaris 8 Operating System
(02/04); Solaris 9 Operating System (04/04 or later) |
| Languages |
C, C++, Pascal, Fortran,
Java |
| Networking |
ONC/NFS, TCP/IP, SunNet
OSI, X.25 Start, DCE, NetWare |
| System management |
Sun MC 3.5 Version 4;
SMS 1.4.1 (or later) |
| Network management |
VERITAS Volume Manager
3.1.1, VERITAS File System 3.4, Sun Cluster 3.0 |
| Storage |
| Standard |
120+ TB direct connect
storage--Fibre Channel (1 GB and 2 GB) and UltraSCSI;
Sun StorEdge 9900, S1, D240, Sun StorEdge 6x00, and Sun
StorEdge 3x00. Direct attach to Sun StorEdge tape libraries
and disk arrays, including: Sun StorEdge 3000, 6000, and
9900, providing excellent linear scalability |
| Environment |
| AC power |
200-240 single-phase
VAC, 47-63 Hz. Two N+1 power grids, each using six 30-Amp
circuits. Second power grid provided for redundancy |
| Optimum |
22 degrees C (72 degrees
F) at 45% noncondensing humidity |
| Range |
10 degrees C to 35 degrees
C (50 degrees F to 90 degrees F) at 20% to 80% noncondensing
humidity |
Altitude |
Up to 3048 m (10000 ft.) |
| Regulations |
|
Meets or exceeds the following requirements: |
| Safety |
UL 60950, third-edition
USA CAN/CSA-C22.2 No.60950-00, Canada EN 60950, third-edition,
Europe S Mark Argentina Gost-R, Russia CB Scheme with
all national differences |
| Emissions |
EN55022 Class A, Europe
EN6100-3-2/ 3-3, Europe FCC Class A, USA ICES-003 Class
A, Canada VCCI Class A, Japan CNS-13438, (BSMI-Taiwan)
AS/NZ 3548 (C-tick), Australia Gost-R, Russia |
| Immunity |
All European requirements
EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5,
EN61000-4-6, EN61000-4-8, EN61000-4-11, and EN300-386 |
| Regulatory Markings |
CE, FCC, ICES-003, C-tick,
VCCI, Gost-R, BSMI, UL/cUL/S Mark, TUV-GS, MIC |
| Dimensions
and Weights |
| Height |
191 cm (74.75 in.) |
| Width |
85 cm (33.25 in.) |
| Depth |
166 cm (65.0 in.) |
| Weight |
1122 kg (2468 lb.) fully
configured |
| Remote
Services |
| System monitoring |
Sun Remote Services Net
Connect |
| Upgrades |
| The Sun Upgrade
Advantage Program (UAP) offers trade-in value for qualified
Sun and competitive servers towards the purchase of replacement
Sun Fire E25K servers. Whether upgrading one system or
consolidating many systems to one, Sun UAP offers the
flexibility to trade-in systems and receive credit towards
the new Sun system purchased. Upgrades are also available
for Sun Fire server system component upgrades including
CPU/memory boards, and I/O assemblies. |